Skip to main content

DGYR 20 ST

Three-phase soundproofed generator set from our Rental Plus range. It is equipped with power sockets and a Rental Plus Kit. Its bench and canopy are made of high-resistance galvanized steel. It also includes other features which make it the perfect choice for demanding contexts and continuous power demands.

This generator is specially designed for its use in rental applications in various fields, such as events, mining, construction or military applications. See below what this rental generator set can offers you.

DGYR 20 ST
*Illustrative image
  • Dimensions (mm)
    L
    1903
    W
    862
    H
    1291
  • Weight (Kg)
    700
  • Fuel tank (l)
    100
  • Voltage
    400/230 V
  • Frequency
    50 Hz
  • 1500r.p.m
  • Water cooled
  • Fuel
    Diesel
  • Version
    Soundproofed
  • CE Conformity

Technical specifications

General technical data Engine YANMAR 4TNV88-BIECS
Alternator STAMFORD S0L2-G
Performance class G2
Frequency 50 Hz
Voltage 400/230 V
Control card DSE 3110 CONTROL CARD
Fuel tank (l) 100
Power ESP Power (kVA / KW) 19 / 15
PRP Power (kVA / KW) 18 / 14
Would you like more information? Technical datasheet or Request information }

Standard equipment

DSE 3110 CONTROL CARD

The Deep Sea Electronics control card DSE 3110 can be utilised as a manual or auto start module for single gen-set applications or engine only applications.

The module has been designed to work with electronic and non-electronic engines, providing advanced engine monitoring and protection features.

The DSE 3110 includes a back-lit icon LCD display which clearly shows the status of the engine at all times. The module monitors engine speed, frequency, voltage and engine run hours and also displays the warning and shutdown status.

The module includes fixed and flexible outputs as well as configurable inputs making this product ideal for a wide variety of applications.

The module can either be programmed using the front panel or by using the DSE Configuration Suite PC software.

DSE 3110 MKII Control Card for Dagartech gensets

Readings allowed by the control card

DSE 3110 MKII Control Card for Dagartech gensets
Engine
Turning speed
Battery voltage
Hours counter
Mains
-
Generator
Genset voltage
Genset frequency
Alarm detected
Start-up failure
High coolant temperature
Low oil pressure
Over/Low speed engine
Charging alternator failure
Low fuel level
High/Low battery voltage
High/Low generator voltage
High/Low generator frequency
External emergency stop
Communication error
Internal memory error

The genset response to a fully configurable alarm is available via DSE 3110 software.

Would you like more information about the control card? Deep Sea Electronics DSE 3110 technical datasheet

Would you like more information? Technical datasheet or Request information

¿Deseas información sobre nuestros grupos electrógenos?

Completa el siguiente formulario, estudiaremos tu caso y te ofreceremos la solución que mejor se adapte a tus necesidades.

Contact data

Información acerca del producto

Información técnica del producto

¿Conoces las especificaciones técnicas del grupo eléctrogeno que necesitas?

Tipo carcasa

Frecuencia

Protection of personal data. We will use your data to send budgets and commercial communications. For more information about the treatment and your rights, consult the privacy policy.< /p>